{"id":7555,"date":"2024-06-17T16:07:17","date_gmt":"2024-06-17T14:07:17","guid":{"rendered":"https:\/\/www.illko.cz\/produkt\/il2550-mdtest\/"},"modified":"2025-02-21T12:37:47","modified_gmt":"2025-02-21T11:37:47","slug":"il2550-mdtest","status":"publish","type":"product","link":"https:\/\/www.illko.cz\/en\/produkt\/il2550-mdtest\/","title":{"rendered":"IL2550 &#8211; MDtest"},"content":{"rendered":"<p><strong>Measurement<\/strong><\/p>\n<ul>\n<li>Continuity with a current of &gt; 1 A<\/li>\n<li>Insulation resistance with a voltage of 500 V and 250 V<\/li>\n<li>Substitute leakage and touch current<\/li>\n<li>Current through the protective conductor and touch current with L and N wire swapping<\/li>\n<li>Differential and touch current with L and N wire swapping<\/li>\n<li>Applied part leakage current of medical electrical equipment<\/li>\n<li>Leakage currents using a three-phase adapter or clamp meter<\/li>\n<li>DC components of selected leakage currents by direct method<\/li>\n<li>Fault (disconnection) simulation of a PE or N conductor for selected leakage currents<\/li>\n<li>Apparent power \/ current drawn by the appliance<\/li>\n<li>Apparent power \/ current using a clamp meter<\/li>\n<li>Mains voltage<\/li>\n<\/ul>\n<p><strong>Other features<\/strong><\/p>\n<ul>\n<li>Alternating quantities are measured using the TRMS method<\/li>\n<li>Measurement of selected quantities in isolated networks (IT)<\/li>\n<li>Possibility to connect additional measuring devices: three-phase adapters, clamp meters, etc.<\/li>\n<li>Graphic OLED display (easy to read in different lighting conditions)<\/li>\n<li>Up to 4,000 appliancecan be stored in the internal memory<\/li>\n<li>USB connector for connecting a barcode reader or RFID chip reader<\/li>\n<li>Data transfer to PC via USB cable<\/li>\n<li>&#8220;Help&#8221; function available directly in the device<\/li>\n<\/ul>\n<p><strong>The device is equipped with a number of control and safety functions<\/strong><\/p>\n<ul>\n<li>Checking the PE pin connection in the power socket before starting the measurement<\/li>\n<li>Checking for dangerous touch voltage on the PE pin in the power socket before starting the measurement<\/li>\n<li>Checking the amount of leakage current during measurement<\/li>\n<li>Checking the amount of electrical current drawn from the power socket<\/li>\n<li>Manual test of the correct device function (AUTOTEST)<\/li>\n<\/ul>\n<p>To increase work productivity and efficiency MDtest device together with its PC software ILLKO Studio is equipped by the appliance database management feature:<\/p>\n<ul>\n<li>Appliance identification using an ID code (barcode)<\/li>\n<li>Possibility to transfer the appliance database or selected database parts from PC to MDtest<\/li>\n<li>Possibility to update the appliance database from the MDtest to PC<\/li>\n<li>Possibility to use automatic workflows during testing<\/li>\n<li>Manual evaluation of the inspection results directly in the device<\/li>\n<li>Possibility to individually modify inspection result forms in PC<\/li>\n<\/ul>\n<p><strong>Package content<\/strong><\/p>\n<ul>\n<li>MDtest measuring device<\/li>\n<li>ILLKO Studio PC software license (the license is loaded in the device)<\/li>\n<li>P2011 &#8211; safety connecting cable (banana\/banana), black, length 2 m<\/li>\n<li>P3011 &#8211; safety measuring tip, black<\/li>\n<li>USB cable<\/li>\n<li>User\u00b4s manual<\/li>\n<li>Calibration certificate<\/li>\n<li>Warranty card<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong>Note:<\/strong> According to the customer&#8217;s wishes, the device can be modified with a different socket and power cord (e.g. Germany, UK, Brazil, Israel, etc.). Modification is possible also for different mains voltage (100 &#8211; 140 V \/ 60 Hz).<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Multifunctional device designed for verifying the safety of medical electrical devices and electrical appliances according to \u010cSN EN 62353, \u010cSN EN 60601-1 ed.2 (partially) and \u010cSN 33 1600 ed.2.<\/p>\n","protected":false},"featured_media":7116,"template":"","meta":{"_et_pb_use_builder":"off","_et_pb_old_content":"<strong>Device\u00b4s functions and features:<\/strong>\r\n\r\n<strong>Measurement<\/strong>\r\n<ul>\r\n \t<li>Insulation resistance with a voltage of 500 V and 250 V<\/li>\r\n \t<li>Continuity with a current of > 1 A, resolution up to 0.001 \u03a9<\/li>\r\n \t<li>Leakage currents of the electrical appliance and applied parts by the substitute method according to \u010cSN EN 62353, resolution up to 0.0001 mA<\/li>\r\n \t<li>Leakage currents of the electrical appliance and applied parts using the direct method according to \u010cSN EN 62353<\/li>\r\n \t<li>Leakage currents of the electrical appliance and applied parts using the differential method according to \u010cSN EN 62353<\/li>\r\n \t<li>Leakage currents according to \u010cSN EN 60601-1 ed.2 (partially)<\/li>\r\n \t<li>Leakage currents according to \u010cSN 33 1600 ed.2<\/li>\r\n \t<li>DC components of selected leakage currents by direct method<\/li>\r\n \t<li>Fault (disconnection) simulation of a PE or N conductor for selected leakage currents<\/li>\r\n \t<li>Apparent power \/ current drawn by the appliance<\/li>\r\n \t<li>Mains voltage<\/li>\r\n \t<li>Leakage current in three-phase appliance with a movable supply using a three-phase adapter<\/li>\r\n \t<li>Apparent power \/ current using a clamp meter<\/li>\r\n<\/ul>\r\n<strong>Other features<\/strong>\r\n<ul>\r\n \t<li>Alternating quantities are measured using the TRMS method<\/li>\r\n \t<li>Measurement of selected quantities in isolated networks (IT)<\/li>\r\n \t<li>USB connector for connecting accessories to the MDtest (e.g. barcode reader)<\/li>\r\n \t<li>USB connector for PC connection<\/li>\r\n \t<li>Graphic OLED display (very easy to read in different lighting conditions)<\/li>\r\n \t<li>Durable foil keyboard<\/li>\r\n \t<li>Separate START button to start the selected measurement<\/li>\r\n<\/ul>\r\n<strong>To increase work productivity and efficiency MDtest together with its software ILLKO Studio is equipped with appliance database management feature: <\/strong>\r\n<ul>\r\n \t<li>Keeping a database of applianceand evaluating the results of the revision<\/li>\r\n \t<li>Two-way communication with a PC via USB interface<\/li>\r\n \t<li>Memory for up to 4000 appliance<\/li>\r\n \t<li>Appliance identification using an ID code (barcode, chip etc.) and reading these IDs by the wireless reader<\/li>\r\n \t<li>Possibility to transfer the appliance database or selected database parts from PC to MDtest<\/li>\r\n \t<li>Possibility to update the appliance database in PC as well as directly in MDtest when working<\/li>\r\n \t<li>Possibility to use automatic workflows during testing<\/li>\r\n \t<li>Evaluation of inspection results directly in the device<\/li>\r\n \t<li>Possibility to individually modify\/edit inspection result forms in PC<\/li>\r\n<\/ul>\r\n<strong>MDtest is equipped with a number of control and safety functions:<\/strong>\r\n<ul>\r\n \t<li>Checking for dangerous touch voltage on the PE pin in the power socket before starting the measurement<\/li>\r\n \t<li>Checking the PE pin connection in the power socket to the PE wire before starting the measurement<\/li>\r\n \t<li>Permanent control of the amount of leakage current during measurement<\/li>\r\n \t<li>Checking the amount of current drawn from the MDtest power socket<\/li>\r\n \t<li>Manual test of the correct device function (AUTOTEST)<\/li>\r\n<\/ul>\r\n<strong>What is leakage?<\/strong>\r\n<ul>\r\n \t<li>The leakage current flows between mutually isolated parts of the appliance (for example, between the mains and accessible parts).<\/li>\r\n \t<li>The size of the leakage current mainly affects the state of insulation between the mutually insulated parts of the appliance, but also the capacitive and inductive forces between these parts.<\/li>\r\n \t<li>By measuring the leakage (touch) current, it is determined what current would flow through the body of a person touching accessible (non-live) parts of a class II appliance. In class I appliance, the measured leakage current would flow through the human body after breaking the protective conductor. <\/li>\r\n<\/ul>\r\n<strong>Calibration of the instrument:<\/strong>\r\nThe MDtest device is not a medical device within the meaning of Act No. 268\/2014 Coll. on Medical Devices and Act No. 366\/2017 Coll. and therefore does not fall within the competence of S\u00daKL.\r\nSee: How often should I calibrate revision instruments and who determines the calibration interval?.   \r\n\r\n<strong>Package content<\/strong>\r\n<ul>\r\n \t<li>MDtest device<\/li>\r\n \t<li>Measuring lead black banana\/banana 2m<\/li>\r\n \t<li>Measuring tip black<\/li>\r\n \t<li>USB cable A-B<\/li>\r\n \t<li>CD (user manual + SW for PC)<\/li>\r\n \t<li>User\u00b4s manual<\/li>\r\n \t<li>Calibration certificate<\/li>\r\n \t<li>Warranty card<\/li>\r\n \t<li>Cardboard box<\/li>\r\n<\/ul>\r\n<a href=\"https:\/\/www.illko.cz\/wp-content\/uploads\/2024\/06\/mdtest-rd.jpg\"><img class=\"alignnone size-medium wp-image-2423\" src=\"https:\/\/www.illko.cz\/wp-content\/uploads\/2024\/06\/mdtest-rd-300x225.jpg\" alt=\"MDTEST Package content\" width=\"300\" height=\"225\"><\/a>","_et_gb_content_width":""},"product_brand":[],"product_cat":[109,112],"product_tag":[111],"class_list":{"0":"post-7555","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-appliance-meters-incl-medical-machines-and-switchboards","7":"product_cat-medical-devices","8":"product_tag-illko-en","9":"pa_vyrobce-illko","11":"first","12":"instock","13":"featured","14":"taxable","15":"shipping-taxable","16":"purchasable","17":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.illko.cz\/en\/wp-json\/wp\/v2\/product\/7555","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.illko.cz\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.illko.cz\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.illko.cz\/en\/wp-json\/wp\/v2\/media\/7116"}],"wp:attachment":[{"href":"https:\/\/www.illko.cz\/en\/wp-json\/wp\/v2\/media?parent=7555"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.illko.cz\/en\/wp-json\/wp\/v2\/product_brand?post=7555"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.illko.cz\/en\/wp-json\/wp\/v2\/product_cat?post=7555"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.illko.cz\/en\/wp-json\/wp\/v2\/product_tag?post=7555"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}